RM Analyzer Help

Action > SupAddLc

Unconditional adding of the (factorized) results of the specified load case to the contents of the treated superposition file .

SettingDescription
Action Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function.
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Input-1 > Superposition file Name of the treated superposition file where the the result values are added.
Input-2 > Load case name Name of the load case to be added (selection in the selection pad)
Input-3 > (Factor 1) Multiplication factor for the added Load Case results, if they are favorable

Default: 1.0

Input-3 > (Factor 2) Multiplication factor for the added Load Case results, if they are unfavorable

Default: 1.0.

Output-1 > (Superposition file) Name of a new superposition file, if the original file must not be overwritten
Note: Any specified existing superposition file will be overwritten
Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)